technical proportions
All loadcells are individually tested and are supplied with a certificate of calibration.
| example: | |||||
| model | 1.00.058 | ||||
| capacity | 4T | ||||
| serial No. | 1234 | ||||
| output | 16.6736 mV/V | ||||
| zero balance | <+/_ 1.00% of full scale | ||||
| creep | <+/_ 0.05% of full scale | ||||
| non linearity | <+/_ 2.50% of full scale | ||||
| hysteresis | <+/_ 1.20% of full scale | ||||
| repeatability | <+/_ 0.03% of full scale | ||||
| temperature effect on output | < 50 PPM/°C of applied load | ||||
| temperature effect on zero | < 50 PPM/°C of applied load | ||||
| temperature range: operating | -20 °C to +60 °C | ||||
| temperature range: compensated | -10 °C to +50 °C | ||||
| safe overload | 120% of capacity | ||||
| imput impendance | 750 +/- 10 Ohms | ||||
| output impendance | 700 +/- 5 Ohms | ||||
| insulation impedance | ≥ 5000 M Ohms | ||||
| exitation: reccomended | 10 V DC/AC | ||||
| exitation: maximum | 20 V DC/AC | ||||
| Colour code: | |||||
| red | + exitation | ||||
| black | - exitation | ||||
| green | + signal | ||||
| white | - signal | ||||